Disjuntor Caixa Moldada (MCCB) com Proteção DR Mitsubishi NF-S 3P 15A 50mA 10kA (400V) NV50-SVFU3P15A50

Consulte as Condições de Fornecimento

Disjuntor Caixa Moldada Mitsubishi NF-S 3P 15A 50mA 10kA (400V) NV50-SVFU3P15A50

SKU: NV50-SVFU3P15A50 Categoria: Marca:

Disjuntor Caixa Moldada (MCCB) Mitsubishi Electric NV50-SVFU3P15A50 com proteção de fuga à terra, 3 polos, corrente nominal de 15A, sensibilidade residual de 50mA e capacidade de interrupção de 10kA. Produto de alta velocidade, série NF-S, com unidade termomagnética fixa. UL 489 Listed. — Saiba mais

Especificações

Parâmetro Valor
Primary brand Mitsubishi
Main function Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / ELCB
Product series / family name UL 489 Listed ELCBs (harmonic surge ready)
Sub-range name NF-S (standard class)
Functions Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB)
Design high-speed type
Poles 3-poles (3P)
Rated current 15A
Trip current rating 15 AT
Frame current rating 50 AF
Residual current sensitivity 50mA
Rated voltage (AC) 120-240Vac (UL 489)
Rated impulse voltage (Uimp) 6 kV
Connection type Front lugs or bars connection
Short circuit breaking rating 14kA (120Vac; UL489) 14kA (240Vac; UL489)
Ultimate short circuit current breaking capacity (Icu) 15kA (100Vac; IEC60947) 15kA (230Vac; IEC60947) 10kA (400Vac; IEC60947) 7.5kA (440Vac; IEC60947)
Service short circuit current breaking capacity (Ics) 8kA (100Vac) 8kA (230Vac) 5kA (400Vac) 4kA (440Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%) (400Vac) 50 %
Trip unit type Thermal-Magnetic (fixed)
Protection functions Thermal protection (Overload) Magnetic protection (Short-circuit) Earth leakage protection
Protection settings Thermal protection (Overload) — tripping threshold fixed at 15A
Mounting mode Surface mounting (or DIN rail with optional adapter)
Dimensions W54mm x H120mm x D90mm
Utilisation category A
Manufacturer product status Commercialized
Equivalent to NV50SVFU3P15A50
Rated Voltage (AC) – Phase-to-phase 100-440 V
Compliant with standard(s) IEC 60947-2 EN 60947-2 UL 489 CSA C22.2 No.5-02 TUV approval CE marking
Benefits The all-new “World Super V Series (WS-V Series)” built with a new breaking technology is designed to respond to the individual market needs of the receiving and distribution and machineries. This series is the result of revolutionary evolution Equipped with a new cutoff technology to enhance interrupting performance Compatible with the latest standards of various countries to deliver optimal performance according to individual needs.
Degree of pollution 2

Documentos

Marca

Mitsubishi Electric