### Especificações | Parâmetro | Valor | | :————————— | :—————————————————————————————————————————————————————————————————————————- | | Marca principal | Mitsubishi Electric | | Função principal | Drive de Velocidade/Frequência Variável (VSD/VFD) / Inversor | | Série/família do produto | FREQROL FR-F800 series | | Frequência da rede (saída) | 0.2-590 Hz | | Projeto | Revestimento estendido, terminal FM (saída PTO), resfriamento a ar forçado | | Tensão de alimentação (CA) | 380Vca-500Vca (400Vca / 415Vca / 480Vca) | | Tipo de rede | Trifásico/3P | | Corrente nominal | 29A (LD Light duty) 31A (SLD Super Light duty) Corrente de sobrecarga 110% In por 60s / 120% In por 3s (características inversamente proporcionais; Super light duty) Corrente de sobrecarga 120% In por 60s / 150% In por 3s (características inversamente proporcionais; Light duty) | | Potência ativa nominal (kW) | 15kW (LD Light duty) 15kW (SLD Super Light Duty) | | Potência nominal (HP) | 20HP (LD Light Duty) 20HP (SLD Super Light Duty) | | Funções de proteção | Falha de sobrecorrente durante aceleração, Falha de sobrecorrente em velocidade constante, Falha de sobrecorrente durante desaceleração ou parada, Falha de sobretensão regenerativa durante aceleração, Falha de sobretensão regenerativa em velocidade constante, Falha de sobretensão regenerativa durante desaceleração ou parada, Falha de sobrecarga do inversor (função relé térmico eletrônico), Falha de sobrecarga do motor (função relé térmico eletrônico), Falha de superaquecimento do dissipador, Parada por stall, Detecção de falha no limite superior, Detecção de falha no limite inferior, Sobrecorrente de falha de aterramento no lado de saída, Sobrecorrente de curto-circuito de saída, Falha de opção de comunicação, Falha de dispositivo de armazenamento de parâmetros, Desconexão da PU, Perda de fase de saída, Falha da CPU, Curto-circuito na alimentação do painel de operação/alimentação dos terminais RS-485, Falha de alimentação 24Vcc, Falha de comunicação (inversor), Falha de entrada analógica, Falha de comunicação USB, Falha do circuito de segurança, Falha do circuito interno, Erro de definição do usuário na função PLC, Detecção de perda de sincronismo (não disponível em status inicial), Operação do relé térmico externo, Operação do termistor PTC, Excesso de contagem de repetição, Detecção de corrente de saída anormal, Ocorrência de sobrevelocidade, Falha de entrada de 4mA, Falha de pré-carga, Falha de sinal PID, Circuito de limitação de corrente de pico, Falha de energia instantânea, Subtensão, Perda de fase de entrada | | Protocolo de comunicação | Modbus RTU | | Entradas digitais | 1 x entrada digital (fonte/dreno) (STF), 1 x entrada digital (fonte/dreno) (STR), 1 x entrada digital (fonte/dreno) (STOP), 1 x entrada digital (fonte/dreno) (RH), 1 x entrada digital (fonte/dreno) (RM), 1 x entrada digital (fonte/dreno) (RL), 1 x entrada digital (fonte/dreno) (JOG), 1 x entrada digital (fonte/dreno) (RT), 1 x entrada digital (fonte/dreno) (MRS), 1 x entrada digital (fonte/dreno) (RES), 1 x entrada digital (fonte/dreno) (AU), 1 x entrada digital (fonte/dreno) (CS), 1 x entrada digital (parada segura SS1 canal 1), 1 x entrada digital (parada segura SS1 canal 2) | | Saídas digitais | 1 x saída digital (contato SPDT (Single Pole Double Throw A1/B1/C1) (programável)), 1 x saída digital (contato SPDT Single Pole Double Throw A2/B2/C2) (programável)), 1 x saída digital (transistor de coletor aberto (dreno/fonte) (RUN; programável)), 1 x saída digital (transistor de coletor aberto (dreno/fonte) (SU; programável)), 1 x saída digital (transistor de coletor aberto (dreno/fonte) (IPF; programável)), 1 x saída digital (transistor de coletor aberto (dreno/fonte) (OL; programável)), 1 x saída digital (transistor de coletor aberto (dreno/fonte) (FU; programável)), 1 x saída digital (PTO Pulse Train Output) (indicador de frequência), 1 x saída digital (programável) (SO – Saída de Monitoramento de Segurança) | | Entradas analógicas | 1 x entrada analógica (0-5Vcc / 0-10Vcc / 4-20mA), 1 x entrada analógica (0-5Vcc / 0-10Vcc), 1 x entrada analógica (0-5Vcc / 0-10Vcc / 4-20mA) | | Saídas analógicas | 1 x saída analógica (0-10Vcc) (saída de sinal) | | Grau de proteção | IP20 | | Resistência química | Resistência química (revestimento da placa de circuito + condutores banhados – IEC60721-3-3 3S2 3C2) | | Tipo de aplicação | Ventilador, Bomba, Ar condicionado | | Código do pedido / SKU | FR-F840-00310-1-N6 | | Status do produto do fabricante | Comercializado | | Equivalente a | FRF840003101N6 | | Em conformidade com padrão(ões) | UL, cUL, CE, KC (Coreia do Sul), Lei de Ondas de Rádio, RoHS, IEC60721-3-3 (3S2; 3C2) |—SEPARATOR—### Documentos * [Mitsubishi Electric – Factory Automation (FA) – FREQROL – FR-F800 Series – Catalog.pdf](https://cdn.kyklo.co/assets/W1siZiIsIjIwMjMvMDEvMTMvMDgvMzYvMTMvNTNiZGMyYjAtNjhlZC00N2FmLWFhMTAtZjg5MGQ2NGQ3YzM4L01pdHN1YmlzaGklMjBFbGVjdHJpYyUyMC0lMjBGYWN0b3J5JTIwQXV0b21hdGlvbiUyMChGQSklMjAtJTIwRlJFUVJPTCUyMC0lMjBGUi1GODAwJTIwU2VyaWVzJTIwLSUyMENhdGFsb2cucGRmIl1d?sha=9b0d319fe04229a1) Este produto é equivalente ao código FRF840003101N6. Para mais informações ou para discutir suas necessidades, entre em contato conosco. [https://mokka-sensors.com.br/#contato](https://mokka-sensors.com.br/#contato)
Especificações
| Parâmetro | Valor |
|---|---|
| Primary brand | Mitsubishi Electric |
| Main function | Variable Speed/Frequency Drive (VSD/VFD) / Inverter |
| Product series / family name | FREQROL FR-F800 series |
| Network frequency | (output) 0.2-590 Hz |
| Functions | Variable Speed/Frequency Drive (VSD/VFD) / Inverter Soft-PWM control High carrier frequency PWM control Advanced magnetic flux vector control PM motor control Maximum and minimum frequency settings Multi-speed operation Acceleration/deceleration pattern Thermal protection DC injection braking Starting frequency JOG operation Output stop (MRS) Stall prevention Regeneration avoidance Increased magnetic excitation deceleration DC feeding Frequency jump Rotation display Automatic restart after instantaneous power failure Electronic bypass sequence Remote setting Retry function Carrier frequency selection Fast-response current limit Forward/reverse rotation prevention Operation mode selection Slip compensation Speed smoothing control Traverse Auto tuning Applied motor selection RS-485 communication PID control PID pre-charge function Cooling fan operation selection Stop selection (deceleration stop/coasting) Power-failure deceleration stop function PLC function Life diagnosis Maintenance timer Current average monitor Multiple rating Test run 24V power supply input for control circuit Safety stop function Self power management BACnet communication PID gain tuning Cleaning Load characteristics storage Emergency drive |
| Design | extended conformal coating FM term. (PTO output) Forced air cooling |
| Supply voltage (AC) | 380Vac-500Vac (400Vac / 415Vac / 480Vac) |
| Type of network | 3-phase/3P |
| Rated current | 29A (LD Light duty) 31A (SLD Super Light duty) 110% In for 60s / 120% In for 3s overload current rating (inverse-time characteristics; Super light duty) 120% In for 60s / 150% In for 3s overload current rating (inverse-time characteristics; Light duty) |
| Rated active power (kW) | 15kW (LD Light duty) 15kW (SLD Super Light Duty) |
| Rated power (HP) | 20HP (LD Light Duty) 20HP (SLD Super Light Duty) |
| Protection functions | Overcurrent trip during acceleration Overcurrent trip during constant speed Overcurrent trip during deceleration or stop Regenerative overvoltage trip during acceleration Regenerative overvoltage trip during constant speed Regenerative overvoltage trip during deceleration or stop Inverter overload trip (electronic thermal relay function) Motor overload trip (electronic thermal relay function) Heatsink overheat Stall prevention stop Upper limit fault detection Lower limit fault detection Output side earth (ground) fault overcurrent Output short-circuit Option fault Communication Option fault Parameter storage device fault PU disconnection Output phase loss CPU fault Operation panel power supply short circuit/RS-485 terminals power supply short circuit 24Vdcpower fault Communication fault (inverter) Analog input fault USB communication fault Safety circuit fault Internal circuit fault User definition error in the PLC function Detection of loss of synchronism detection (not available in initial status) External thermal relay operation PTC thermistor operation Retry count excess Abnormal output current detection Overspeed occurrence 4mA input fault Pre-charge fault PID signal fault Inrush current limit circuit fault Instantaneous power failure Undervoltage Input phase loss |
| Communication protocol | Modbus RTU |
| Digital inputs | 1 x digital input (source/sink) (STF) 1 x digital input (source/sink) (STR) 1 x digital input (source/sink) (STOP) 1 x digital input (source/sink) (RH) 1 x digital input (source/sink) (RM) 1 x digital input (source/sink) (RL) 1 x digital input (source/sink) (JOG) 1 x digital input (source/sink) (RT) 1 x digital input (source/sink) (MRS) 1 x digital input (source/sink) (RES) 1 x digital input (source/sink) (AU) 1 x digital input (source/sink) (CS) 1 x digital input (SS1 safe stop channel 1) 1 x digital input (SS1 safe stop channel 2) |
| Digital outputs | 1 x digital output (SPDT (Single Pole Double Throw contact A1/B1/C1) (programmable) 1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable) 1 x digital output (sink/source open collector transistor) (RUN; programmable) 1 x digital output (sink/source open collector transistor) (SU; programmable) 1 x digital output (sink/source open collector transistor) (IPF; programmable) 1 x digital output (sink/source open collector transistor) (OL; programmable) 1 x digital output (sink/source open collector transistor) (FU; programmable) 1 x digital output (PTO Pulse Train Output) (Frequency meter indicator) 1 x digital output (programmable) (SO – Safety Monitor Output) |
| Analog inputs | 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA) 1 x analog input (0-5Vdc / 0-10Vdc) 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA) |
| Analog outputs | 1 x analog output (0-10Vdc) (signal output) |
| Degree of protection | IP20 |
| Chemical resistance | Chemical resistance (circuit board coating + plated conductors – IEC60721-3-3 3S2 3C2) |
| Application type | Fan Pump Air conditioning |
| Order code / Manufacturer SKU | FR-F840-00310-1-N6 |
| Manufacturer product status | Commercialized |
| Equivalent to | FRF840003101N6 |
| Compliant with standard(s) | UL cUL CE KC (South Korea) Radio Waves Act RoHS IEC60721-3-3 (3S2; 3C2) |