Inversor de Frequência FR-A800 Mitsubishi 75HP 600V Ethernet IP55 Este Inversor de Frequência Mitsubishi Electric FR-A800, com código FR-A860-01080-E160, é um dispositivo de controle de velocidade projetado para aplicações industriais exigentes. Oferece uma solução robusta com revestimento protetor e saída PTO, garantindo desempenho confiável em ambientes desafiadores.
Especificações
| Parâmetro | Valor |
|---|---|
| Primary brand | Mitsubishi Electric |
| Main function | Variable Speed/Frequency Drive (VSD/VFD) / Inverter |
| Product series / family name | FREQROL FR-A800 series |
| Network frequency | (output) 0.2-590 Hz |
| Functions | Variable Speed/Frequency Drive (VSD/VFD) / Inverter Soft-PWM control High carrier frequency PWM control PM sensorless vector control Maximum and minimum frequency settings Multi-speed operation Acceleration/deceleration pattern Thermal protection DC injection braking Starting frequency JOG operation Output stop (MRS) Stall prevention Regeneration avoidance Increased magnetic excitation deceleration Frequency jump Rotation display Automatic restart after instantaneous power failure Electronic bypass sequence Remote setting Automatic acceleration/deceleration Retry function Carrier frequency selection Fast-response current limit Forward/reverse rotation prevention Operation mode selection Slip compensation Droop control Load torque high-speed frequency control Speed smoothing control Traverse Auto tuning Applied motor selection Gain tuning RS-485 communication PID control PID pre-charge function Easy dancer control Cooling fan operation selection Stop selection (deceleration stop/coasting) Power-failure deceleration stop function Stop-on-contact control PLC function Life diagnosis Maintenance timer Current average monitor Multiple rating Speed control Torque control Position control Pre-excitation Torque limit Test run 24V power supply input for control circuit Safety stop function Anti-sway control |
| Design | Ethernet card conformal coating FM term. (PTO output) Fan cooling + internal fan |
| Supply voltage (AC) | 600Vac |
| Type of network | 3-phase/3P |
| Rated power (HP) | 75HP |
| Protection functions | Overcurrent trip during acceleration Overcurrent trip during constant speed Overcurrent trip during deceleration or stop Regenerative overvoltage trip during acceleration Regenerative overvoltage trip during constant speed Regenerative overvoltage trip during deceleration or stop Inverter overload trip Motor overload trip Heatsink overheat Stall prevention stop Upper limit fault detection Lower limit fault detection Output side earth (ground) fault overcurrent Output short-circuit Output phase loss Option fault Communication Option fault Parameter storage device fault PU disconnection CPU fault Operation panel power Supply short circuit/RS-485 terminals power supply short circuit 24Vdcpower fault Communication fault Analog input fault USB communication fault Safety circuit fault Opposite rotation Internal circuit fault External thermal relay operation (not available in initial status) Loss of synchronism detection PTC thermistor operation Retry count excess Abnormal output current detection Brake sequence fault 4mA input fault Pre-charge fault PID signal fault Deceleration fault Instantaneous power failure Undervoltage Input phase loss Inrush current limit circuit fault Overspeed occurrence Abnormal internal temperature |
| Communication protocol | Ethernet |
| Digital inputs | 1 x digital input (source/sink) (STF) 1 x digital input (source/sink) (STR) 1 x digital input (source/sink) (STOP) 1 x digital input (source/sink) (RH) 1 x digital input (source/sink) (RM) 1 x digital input (source/sink) (RL) 1 x digital input (source/sink) (JOG) 1 x digital input (source/sink) (RT) 1 x digital input (source/sink) (MRS) 1 x digital input (source/sink) (RES) 1 x digital input (source/sink) (AU) 1 x digital input (source/sink) (CS) 1 x digital input (SS1 safe stop channel 1) 1 x digital input (SS1 safe stop channel 2) |
| Digital outputs | 1 x digital output (SPDT (Single Pole Double Throw contact A1/B1/C1) (programmable) 1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable) 1 x digital output (sink/source open collector transistor) (RUN; programmable) 1 x digital output (sink/source open collector transistor) (SU; programmable) 1 x digital output (sink/source open collector transistor) (IPF; programmable) 1 x digital output (sink/source open collector transistor) (OL; programmable) 1 x digital output (sink/source open collector transistor) (FU; programmable) 1 x digital output (PTO Pulse Train Output) (Frequency meter indicator) 1 x digital output (programmable) (SO – Safety Monitor Output) |
| Analog inputs | 1 x analog input (0-5Vdc / 0-10Vdc / 0-20mA) 1 x analog input (0-5Vdc / 0-10Vdc) 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA) |
| Analog outputs | 1 x analog output (0-10Vdc) (signal output) |
| Degree of protection | IP55 |
| Chemical resistance | Chemical resistance (circuit board coating – IEC60721-3-3 3S2 3C2) |
| Application type | Transfer Lift Food Packaging Machine tool Press Printing Winding/unwinding |
| Order code / Manufacturer SKU | FR-A860-01080-E160 |
| Manufacturer product status | Commercialized |
| Equivalent to | FRA86001080E160 |
| Compliant with standard(s) | IEC60721-3-3 (3S2; 3C2) |