Inversor de Frequência FR-A800 Mitsubishi 355kW/475HP 380-500V 683A Ethernet IP00 com Revestimento, Saída PTO FR-A842-08660-E1U6

Consulte as Condições de Fornecimento

### Principais recursos * Controle de velocidade/frequência variável (VSD/VFD) * Comunicação Ethernet integrada * Revestimento protetor para placas de

SKU: FR-A842-08660-E1U6 Categoria: Marca:

### Especificações | Parâmetro | Valor

Especificações

Parâmetro Valor
Primary brand Mitsubishi Electric
Main function Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family name FREQROL FR-A800 series
Network frequency (output) 0.2-590 Hz
Functions Variable Speed/Frequency Drive (VSD/VFD) / Inverter Soft-PWM control High carrier frequency PWM control Optimum excitation control Maximum and minimum frequency settings Multi-speed operation Acceleration/deceleration pattern Thermal protection DC injection braking Starting frequency JOG operation Output stop (MRS) Stall prevention Regeneration avoidance Increased magnetic excitation deceleration Frequency jump Rotation display Automatic restart after instantaneous power failure Electronic bypass sequence Remote setting Automatic acceleration/deceleration Retry function Carrier frequency selection Fast-response current limit Forward/reverse rotation prevention Operation mode selection Slip compensation Droop control Load torque high-speed frequency control Speed smoothing control Traverse Auto tuning Applied motor selection Gain tuning RS-485 communication PID control PID pre-charge function Easy dancer control Cooling fan operation selection Stop selection (deceleration stop/coasting) Power-failure deceleration stop function Stop-on-contact control PLC function Life diagnosis Maintenance timer Current average monitor Multiple rating Speed control Torque control Position control Pre-excitation Torque limit Test run 24V power supply input for control circuit Safety stop function Anti-sway control
Design separate converter (FR-CC2; sold separately) Ethernet card conformal coating FM term. (PTO output) Forced air cooling
Supply voltage (AC) 380Vac-500Vac (400Vac / 415Vac / 480Vac)
Type of network 3-phase/3P
Rated current 683A (ND Normal Duty) 866A (SLD Super Light duty) 770A (LD Light duty) 610A (HD Heavy Duty) 150% In for 60s / 200% In for 3s overload current rating (inverse-time characteristics; Normal duty; 50°C ambient air temperature) 110% In for 60s / 120% In for 3s overload current rating (inverse-time characteristics; Super light duty; 40°C ambient air temperature) 120% In for 60s / 150% In for 3s overload current rating (inverse-time characteristics; Light duty; 50°C ambient air temperature) 200% In for 60s / 250% In for 3s overload current rating (inverse-time characteristics; Heavy duty; 50°C ambient air temperature)
Rated active power (kW) 355kW (ND Normal Duty) 450kW (SLD Super Light Duty) 400kW (LD Light duty) 315kW (HD Heavy Duty)
Rated power (HP) 475HP (ND Normal Duty) 600HP (SLD Super Light Duty) 535HP (LD Light duty) 420HP (HD Heavy Duty)
Protection functions Overcurrent trip during acceleration Overcurrent trip during constant speed Overcurrent trip during deceleration or stop Regenerative overvoltage trip during acceleration Regenerative overvoltage trip during constant speed Regenerative overvoltage trip during deceleration or stop Inverter overload trip (electronic thermal relay function) Motor overload trip (electronic thermal relay function) Heatsink overheat Stall prevention stop Output side earth (ground) fault overcurrent Output short-circuit Output phase loss Option fault Communication Option fault Parameter storage device fault PU disconnection Parameter storage device fault CPU fault Operation panel power supply short circuit/RS-485 terminals power supply short circuit 24Vdcpower fault Communication fault (inverter) Analog input fault USB communication fault Safety circuit fault Option fault Internal circuit fault Encoder pulse number setting error Overload trip External thermal relay operation (not available in initial status) PTC thermistor operation Retry count excess Abnormal output current detection Overspeed occurrence Speed deviation excess detection Signal loss detection Encoder phase fault 4mA input fault PID signal fault Opposite rotation deceleration fault
Communication protocol Ethernet
Digital inputs 1 x digital input (source/sink) (STF) 1 x digital input (source/sink) (STR) 1 x digital input (source/sink) (STOP) 1 x digital input (source/sink) (RH) 1 x digital input (source/sink) (RM) 1 x digital input (source/sink) (RL) 1 x digital input (source/sink) (JOG) 1 x digital input (source/sink) (RT) 1 x digital input (source/sink) (MRS) 1 x digital input (source/sink) (RES) 1 x digital input (source/sink) (AU) 1 x digital input (source/sink) (CS) 1 x digital input (SS1 safe stop channel 1) 1 x digital input (SS1 safe stop channel 2)
Digital outputs 1 x digital output (SPDT (Single Pole Double Throw contact A1/B1/C1) (programmable) 1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable) 1 x digital output (sink/source open collector transistor) (RUN; programmable) 1 x digital output (sink/source open collector transistor) (SU; programmable) 1 x digital output (sink/source open collector transistor) (IPF; programmable) 1 x digital output (sink/source open collector transistor) (OL; programmable) 1 x digital output (sink/source open collector transistor) (FU; programmable) 1 x digital output (PTO Pulse Train Output) 1 x digital output (programmable) (SO – Safety Monitor Output)
Analog inputs 1 x analog input (0-5Vdc / 0-10Vdc / 0-20mA) 1 x analog input (0-5Vdc / 0-10Vdc) 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA)
Analog outputs 1 x analog output (0-10Vdc)
Degree of protection IP00
Chemical resistance Chemical resistance (circuit board coating – IEC60721-3-3 3S2 3C2)
Rated apparent power (S) 521kVA (ND Normal Duty) 660kVA (SLD Super Light Duty) 587kVA (LD Light duty) 465kVA (HD Heavy Duty)
Application type Transfer Lift Food Packaging Machine tool Press Printing Winding/unwinding
Order code / Manufacturer SKU FR-A842-08660-E1U6
Manufacturer product status Commercialized
Equivalent to FRA84208660E1U6
Compliant with standard(s) UL cUL CE KC (South Korea) Radio Waves Act EAC RoHS

Documentos

Entre em Contato

Marca

Mitsubishi Electric