Inversor de Frequência FR-F800 Mitsubishi 500kW/675HP 380-500Vca 962A Modbus RTU Saída PTO FR-F842-500K-1

Consulte as Condições de Fornecimento

Inversor de Frequência Mitsubishi FR-F800 500kW 380-500V FR-F842-500K-1

SKU: FR-F842-500K-1 Categoria: Marca:

Inversor de Frequência Mitsubishi Electric FREQROL FR-F800 FR-F842-500K-1 para aplicações em 380-500Vca, 500kW, com comunicação Modbus RTU e saída PTO.

Especificações

Parâmetro Valor
Primary brand Mitsubishi Electric
Main function Variable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family name FREQROL FR-F800 series
Network frequency (output) 0.2-590 Hz
Functions Variable Speed/Frequency Drive (VSD/VFD) / Inverter Soft-PWM control High carrier frequency PWM control Advanced magnetic flux vector control PM motor control Maximum and minimum frequency settings Multi-speed operation Acceleration/deceleration pattern Thermal protection DC injection braking Starting frequency JOG operation Output stop (MRS) Stall prevention Regeneration avoidance Increased magnetic excitation deceleration Frequency jump Rotation display Automatic restart after instantaneous power failure Electronic bypass sequence Remote setting Retry function Carrier frequency selection Fast-response current limit Forward/reverse rotation prevention Operation mode selection Slip compensation Speed smoothing control Traverse Auto tuning Applied motor selection RS-485 communication PID control PID pre-charge function Cooling fan operation selection Stop selection (deceleration stop/coasting) Power-failure deceleration stop function PLC function Life diagnosis Maintenance timer Current average monitor Multiple rating Test run 24V power supply input for control circuit Safety stop function Self power management BACnet communication PID gain tuning Cleaning Load characteristics storage
Design separate converter (FR-CC2; sold separately) FM term. (PTO output) Forced air cooling
Supply voltage (AC) 380Vac-500Vac (400Vac / 415Vac / 480Vac)
Type of network 3-phase/3P
Rated current 962A (LD Light duty) 1094A (SLD Super Light duty) 110% In for 60s / 120% In for 3s overload current rating (inverse-time characteristics; Super light duty) 120% In for 60s / 150% In for 3s overload current rating (inverse-time characteristics; Light duty)
Rated active power (kW) 500kW (LD Light duty) 560kW (SLD Super Light Duty)
Rated power (HP) 675HP (LD Light Duty) 750HP (SLD Super Light Duty)
Protection functions Overcurrent trip during acceleration Overcurrent trip during constant speed Overcurrent trip during deceleration or stop Regenerative overvoltage trip during acceleration Regenerative overvoltage trip during constant speed Regenerative overvoltage trip during deceleration or stop Inverter overload trip (electronic thermal relay function) Motor overload trip (electronic thermal relay function) Heatsink overheat Stall prevention stop Upper limit fault detection Lower limit fault detection Output side earth (ground) fault overcurrent Output short-circuit Option fault Communication Option fault Parameter storage device fault PU disconnection Output phase loss CPU fault Operation panel power supply short circuit/RS-485 terminals power supply short circuit 24Vdcpower fault Communication fault (inverter) Analog input fault USB communication fault Safety circuit fault Internal circuit fault User definition error in the PLC function Detection of loss of synchronism detection (not available in initial status) External thermal relay operation PTC thermistor operation Retry count excess Abnormal output current detection Overspeed occurrence 4mA input fault Pre-charge fault PID signal fault
Communication protocol Modbus RTU
Digital inputs 1 x digital input (source/sink) (STF) 1 x digital input (source/sink) (STR) 1 x digital input (source/sink) (STOP) 1 x digital input (source/sink) (RH) 1 x digital input (source/sink) (RM) 1 x digital input (source/sink) (RL) 1 x digital input (source/sink) (JOG) 1 x digital input (source/sink) (RT) 1 x digital input (source/sink) (MRS) 1 x digital input (source/sink) (RES) 1 x digital input (source/sink) (AU) 1 x digital input (source/sink) (CS) 1 x digital input (SS1 safe stop channel 1) 1 x digital input (SS1 safe stop channel 2)
Digital outputs 1 x digital output (SPDT (Single Pole Double Throw contact A1/B1/C1) (programmable) 1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable) 1 x digital output (sink/source open collector transistor) (RUN; programmable) 1 x digital output (sink/source open collector transistor) (SU; programmable) 1 x digital output (sink/source open collector transistor) (IPF; programmable) 1 x digital output (sink/source open collector transistor) (OL; programmable) 1 x digital output (sink/source open collector transistor) (FU; programmable) 1 x digital output (PTO Pulse Train Output) (Frequency meter indicator) 1 x digital output (programmable) (SO – Safety Monitor Output)
Analog inputs 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA) 1 x analog input (0-5Vdc / 0-10Vdc) 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA)
Analog outputs 1 x analog output (0-10Vdc) (signal output) 1 x analog output (0-20mA)
Degree of protection IP00
Application type Fan Pump Air conditioning
Order code / Manufacturer SKU FR-F842-500K-1
Manufacturer product status Commercialized
Equivalent to FRF842500K1
Compliant with standard(s) UL cUL CE KC (South Korea) Radio Waves Act RoHS

Documentos

Entre em Contato

Marca

Mitsubishi Electric