### Especificações | Parâmetro | Valor | | :—————————— | :——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————- | | Marca principal | Mitsubishi Electric | | Função principal | Inversor de Frequência Variável (VSD/VFD) | | Série / nome da família do produto | FREQROL FR-F800 series | | Frequência da rede (saída) | 0.2-590 Hz | | Design | Terminal FM (Saída PTO) Resfriamento por ar forçado | | Tensão de alimentação (CA) | 380Vac-500Vac (400Vac / 415Vac / 480Vac) | | Tipo de rede | Trifásico/3P | | Corrente nominal | 106A (LD Light duty) 116A (SLD Super Light duty) 110% In por 60s / 120% In por 3s (corrente de sobrecarga, características de tempo inverso; Super light duty) 120% In por 60s / 150% In por 3s (corrente de sobrecarga, características de tempo inverso; Light duty) | | Potência ativa nominal (kW) | 55kW (LD Light duty) 55kW (SLD Super Light Duty) | | Potência nominal (HP) | 75HP (LD Light Duty) 75HP (SLD Super Light Duty) | | Funções de proteção | Trip por sobrecorrente durante aceleração, em velocidade constante, ou durante desaceleração/parada; Trip por sobretensão regenerativa durante aceleração, em velocidade constante, ou durante desaceleração/parada; Trip por sobrecarga do inversor (função relé térmico eletrônico); Trip por sobrecarga do motor (função relé térmico eletrônico); Sobreaquecimento do dissipador de calor; Prevenção de stall; Detecção de falha limite superior; Detecção de falha limite inferior; Falha de aterramento no lado da saída; Curto-circuito na saída; Falha de opção de comunicação; Falha de dispositivo de armazenamento de parâmetros; Desconexão da PU; Perda de fase de saída; Falha de CPU; Curto-circuito na fonte de alimentação do painel de operação/ fonte de alimentação dos terminais RS-485; Falha na fonte de alimentação de 24Vcc; Falha de comunicação (inversor); Falha de entrada analógica; Falha de comunicação USB; Falha de circuito de segurança; Falha de circuito interno; Erro de definição do usuário na função PLC; Detecção de perda de sincronismo (não disponível em estado inicial); Operação de relé térmico externo; Operação de termistor PTC; Excesso de contagem de retentativas; Detecção de corrente de saída anormal; Ocorrência de sobrevelocidade; Falha de entrada de 4mA; Falha de pré-carga; Falha de sinal PID; Circuito de limitação de corrente de surto; Falha instantânea de energia; Subtensão; Perda de fase de entrada. | | Protocolo de comunicação | Modbus RTU | | Entradas digitais | 1 x entrada digital (fonte/sink) (STF) 1 x entrada digital (fonte/sink) (STR) 1 x entrada digital (fonte/sink) (STOP) 1 x entrada digital (fonte/sink) (RH) 1 x entrada digital (fonte/sink) (RM) 1 x entrada digital (fonte/sink) (RL) 1 x entrada digital (fonte/sink) (JOG) 1 x entrada digital (fonte/sink) (RT) 1 x entrada digital (fonte/sink) (MRS) 1 x entrada digital (fonte/sink) (RES) 1 x entrada digital (fonte/sink) (AU) 1 x entrada digital (fonte/sink) (CS) 1 x entrada digital (canal de parada segura SS1 1) 1 x entrada digital (canal de parada segura SS1 2) | | Saídas digitais | 1 x saída digital (contato SPDT A1/B1/C1) (programável) 1 x saída digital (contato SPDT A2/B2/C2) (programável) 1 x saída digital (transistor coletor aberto sink/source) (RUN; programável) 1 x saída digital (transistor coletor aberto sink/source) (SU; programável) 1 x saída digital (transistor coletor aberto sink/source) (IPF; programável) 1 x saída digital (transistor coletor aberto sink/source) (OL; programável) 1 x saída digital (transistor coletor aberto sink/source) (FU; programável) 1 x saída digital (PTO Pulse Train Output) (Indicador de frequência) 1 x saída digital (programável) (SO – Saída de Monitoramento de Segurança) | | Entradas analógicas | 1 x entrada analógica (0-5Vcc / 0-10Vcc / 4-20mA) 1 x entrada analógica (0-5Vcc / 0-10Vcc) 1 x entrada analógica (0-5Vcc / 0-10Vcc / 4-20mA) | | Saídas analógicas | 1 x saída analógica (0-10Vcc) (saída de sinal) | | Grau de proteção | IP00 | | Tipo de aplicação | Ventilador Bomba Ar condicionado | | Código de pedido / SKU do fabricante | FR-F840-55K-1 | | Status do produto do fabricante | Comercializado | | Equivalente a | FRF84055K1 | | Em conformidade com as normas | UL cUL CE KC (Coreia do Sul) Lei de Ondas de Rádio RoHS | ### Documentos * [Mitsubishi Electric – Factory Automation (FA) – FREQROL – FR-F800 Series – Catalog.pdf](https://cdn.kyklo.co/assets/W1siZiIsIjIwMjMvMDEvMTMvMDgvMzYvMTMvNTNiZGMyYjAtNjhlZC00N2FmLWFhMTAtZjg5MGQ2NGQ3YzM4L01pdHN1YmlzaGklMjBFbGVjdHJpYyUyMC0lMjBGYWN0b3J5JTIwQXV0b21hdGlvbiUyMChGQSklMjAtJTIwRlJFUVJPTCUyMC0lMjBGUi1GODAwJTIwU2VyaWVzJTIwLSUyMENhdGFsb2cucGRmIl1d?sha=9b0d319fe04229a1) O Inversor de Frequência FR-F840-55K-1 é equivalente ao FRF84055K1 e está em conformidade com as normas UL, cUL, CE, KC e RoHS. Para mais informações ou para discutir suas necessidades, entre em contato conosco. Entre em contato
Especificações
| Parâmetro | Valor |
|---|---|
| Primary brand | Mitsubishi Electric |
| Main function | Variable Speed/Frequency Drive (VSD/VFD) / Inverter |
| Product series / family name | FREQROL FR-F800 series |
| Network frequency | (output) 0.2-590 Hz |
| Functions | Variable Speed/Frequency Drive (VSD/VFD) / Inverter Soft-PWM control High carrier frequency PWM control Advanced magnetic flux vector control PM motor control Maximum and minimum frequency settings Multi-speed operation Acceleration/deceleration pattern Thermal protection DC injection braking Starting frequency JOG operation Output stop (MRS) Stall prevention Regeneration avoidance Increased magnetic excitation deceleration DC feeding Frequency jump Rotation display Automatic restart after instantaneous power failure Electronic bypass sequence Remote setting Retry function Carrier frequency selection Fast-response current limit Forward/reverse rotation prevention Operation mode selection Slip compensation Speed smoothing control Traverse Auto tuning Applied motor selection RS-485 communication PID control PID pre-charge function Cooling fan operation selection Stop selection (deceleration stop/coasting) Power-failure deceleration stop function PLC function Life diagnosis Maintenance timer Current average monitor Multiple rating Test run 24V power supply input for control circuit Safety stop function Self power management BACnet communication PID gain tuning Cleaning Load characteristics storage Emergency drive |
| Design | FM term. (PTO output) Forced air cooling |
| Supply voltage (AC) | 380Vac-500Vac (400Vac / 415Vac / 480Vac) |
| Type of network | 3-phase/3P |
| Rated current | 106A (LD Light duty) 116A (SLD Super Light duty) 110% In for 60s / 120% In for 3s overload current rating (inverse-time characteristics; Super light duty) 120% In for 60s / 150% In for 3s overload current rating (inverse-time characteristics; Light duty) |
| Rated active power (kW) | 55kW (LD Light duty) 55kW (SLD Super Light Duty) |
| Rated power (HP) | 75HP (LD Light Duty) 75HP (SLD Super Light Duty) |
| Protection functions | Overcurrent trip during acceleration Overcurrent trip during constant speed Overcurrent trip during deceleration or stop Regenerative overvoltage trip during acceleration Regenerative overvoltage trip during constant speed Regenerative overvoltage trip during deceleration or stop Inverter overload trip (electronic thermal relay function) Motor overload trip (electronic thermal relay function) Heatsink overheat Stall prevention stop Upper limit fault detection Lower limit fault detection Output side earth (ground) fault overcurrent Output short-circuit Option fault Communication Option fault Parameter storage device fault PU disconnection Output phase loss CPU fault Operation panel power supply short circuit/RS-485 terminals power supply short circuit 24Vdcpower fault Communication fault (inverter) Analog input fault USB communication fault Safety circuit fault Internal circuit fault User definition error in the PLC function Detection of loss of synchronism detection (not available in initial status) External thermal relay operation PTC thermistor operation Retry count excess Abnormal output current detection Overspeed occurrence 4mA input fault Pre-charge fault PID signal fault Inrush current limit circuit fault Instantaneous power failure Undervoltage Input phase loss |
| Communication protocol | Modbus RTU |
| Digital inputs | 1 x digital input (source/sink) (STF) 1 x digital input (source/sink) (STR) 1 x digital input (source/sink) (STOP) 1 x digital input (source/sink) (RH) 1 x digital input (source/sink) (RM) 1 x digital input (source/sink) (RL) 1 x digital input (source/sink) (JOG) 1 x digital input (source/sink) (RT) 1 x digital input (source/sink) (MRS) 1 x digital input (source/sink) (RES) 1 x digital input (source/sink) (AU) 1 x digital input (source/sink) (CS) 1 x digital input (SS1 safe stop channel 1) 1 x digital input (SS1 safe stop channel 2) |
| Digital outputs | 1 x digital output (SPDT (Single Pole Double Throw contact A1/B1/C1) (programmable) 1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable) 1 x digital output (sink/source open collector transistor) (RUN; programmable) 1 x digital output (sink/source open collector transistor) (SU; programmable) 1 x digital output (sink/source open collector transistor) (IPF; programmable) 1 x digital output (sink/source open collector transistor) (OL; programmable) 1 x digital output (sink/source open collector transistor) (FU; programmable) 1 x digital output (PTO Pulse Train Output) (Frequency meter indicator) 1 x digital output (programmable) (SO – Safety Monitor Output) |
| Analog inputs | 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA) 1 x analog input (0-5Vdc / 0-10Vdc) 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA) |
| Analog outputs | 1 x analog output (0-10Vdc) (signal output) |
| Degree of protection | IP00 |
| Application type | Fan Pump Air conditioning |
| Order code / Manufacturer SKU | FR-F840-55K-1 |
| Manufacturer product status | Commercialized |
| Equivalent to | FRF84055K1 |
| Compliant with standard(s) | UL cUL CE KC (South Korea) Radio Waves Act RoHS |